Wall mounted sprinkler coverage.
Sprinklers are available in a nearly unlimited variety of custom color finishes.
Maximum coverage standard spray coverage is up to.
Pendent and upright sprinkler heads keep this minimum distance from all walls 10 2 5 3.
Extended coverage sprinklers have a water distribution radius of a little over 10 feet so they can be spaced approximately 20 feet apart.
Upright sprinklers are installed where obstructions interfere with coverage and in dry pipe systems facing freezing temperatures.
Technical specification sprinkler head horizontal sidewall sprinkler sprinkler identification number standard sd1133 bulb 5mm quick response sd1121 bulb 3mm style horizontal sidewall.
Below the sprinklers has been revised.
A note to our community regarding covid 19.
If you plan on attaching your sprinkler head to the hose check out the possibilities that lowes offers.
For sidewall heads that s the distance from an end wall 10 3 4 3 1.
The distance between light fixtures or similar obstructions located more than 8 ft 2 3 m from the sprinkler shall be in conformity with table 4 9 5 1 2 and figure 4 9 5 1 2 the problem at that time was that table 4 9 5 1 2 for extended coverage sidewall sprinklers did not have a similar allowance for obstructions closer to the sprinkler.
Light hazard 196 square feet 18 2 sq m.
They install deflector up to cover specific areas and to prevent ice and debris from collecting in the head.
The 2013 edition added the allowance with language requiring the shelving to extend above the 18 in.
All standard sprinkler heads pendent upright and sidewall have the same minimum sprinkler distance from walls.
Ordinary hazard 100 square feet 9 3 sq m per nfpa 13.
Home depot carries sprinklers that can be used for above ground or in ground irrigation systems.
Lowes has a great selection of sprinkler heads including an extensive collection of above ground options.
In areas of unobstructed ceiling construction where a vertical change in ceiling elevation within the area of sprinkler coverage creates a distance of more than 3 ft between the upper ceiling and the sprinkler deflector the vertical plane extending down from the ceiling at the change in elevation shall be considered a wall.
In these cases extended coverage sprinkler heads can be installed to increase the spacing between heads.
In some circumstances standard distribution sprinkler heads will not provide enough coverage.
The section allowing wall mounted shelving that is not located directly below a sprinkler to extend above a plane that is 18 in.
Vk479 residential horizontal sidewall sprinkler k3 0 vk486 residential horizontal sidewall sprinkler k4 0.